SINGLE FETUS INTRAPARTUM ACTOCARDIOGRAPH
Versatile, reliable, and durable, the MT-332 allows for comprehensive assessment of single fetus well-being when all the features of the Actocardiography are used. In addition to the detection and recording of Fetal Heart Rate (FHR) and Uterine Contractions (UC), pulsed ultrasound doppler signals automatically detect Fetal Movement (FM). The FM is automatically recorded as an event dot or in spike waveform depending on the clinician's preference. Maternal perception of FM can also be recorded using the event marker.
Compact, lightweight and portable, the MT-332 is conducive to all clinical settings, from physician's offices to Labor and Delivery suites. It can be adapted to each patient situation, providing antepartum NSTs as well as FECG and intrauterine pressure measurements.
Audible and visual FHR alarms
On/off autocorrelation FECG
NST timer
Fetal Heart Rate Output Signal Ultrasound Pulsed Doppler, 1.1 MHz Ultrasound Wave Intensity ≤ 1.5 mW/cm² Detection Method Ultrasound Pulsed Doppler Measurement Method "Instantaneous" Autocorrelation Selectable on/off autocorrelation FECG Range 50-212 beats per minute (BPM) doppler 30-240 BPM FECG Accuracy - o.5% Calibration Point factory set Display FHR - Numeric 30-240 BPM Heartbeat Rhythm - Heart symbol illuminated in synchronization with FHR Signal/Noise - Transducer symbol color changes with signal quality Heartbeat Sound Monitoring Original sound via doppler Transformed sound via FECG Alarms Selectable FHR upper and lower limits Selectable alarm delay setting Tachycardia and bradycardia audible alarms are simultaneous with visual display that blinks and turns red Fetal Movement (FM) Detection Source Ultrasound Pulsed Doppler Recording Spike waveform on uterine contraction channel | denotes relative intensity and duration of FM and/or Dot marks between FHR and uterine contraction channels when FM intensity exceeds selected threshold Dimensions 9.0 W x 9.5H x 14.0D inches 203W x 241H x 3545D millimeters | Uterine Contraction (UC) Input Source External tocodynamometer Intrauterine pressure catheter One-touch zero-level button Recorder Recording Method Auto-balancing thermal pen (2 channels) 8-dot print head for alphanumerics/FM dot Recording Width 1st channel (FHR) 80 mm (50-210 BPM) 70 mm (30-240 BPM) 2nd channel (UC) - 40mm Chart Information Automatic annotation of date, time minute mark, monitoring mode and institution FHR Tracing FM Spike Waveform FM Dot Mark UC Curve Event Mark from remote marker Time recorded every five minutes Paper Speed (CM/min) - 1, 2, or 3 Paper Thermosensitive Z-folded External Output Signals FHR and FHR Alarms FM UC Power Requirements 90-130 VAC, 50/60 Hz, 40VA or 180-260 VAC, 50/60 z, 40VA Weight 22 pounds/10 Kilograms Design and specifications are subject to change without notice |
Tidak ada komentar:
Posting Komentar