Rugged, lightweight, and portable this small Actocardiograph is an excellent choice for all phases of antepartum fetal monitoring.
Simplicity of use begins with easy chart paper loading and extends to all operational characteristics of the MT-325.
A proprietary feature eases the task of doing fetal nonstress tests (NST). Fetal Movement (FM) is detected and recorded automatically, concurrent with Fetal Heart Rate (FHR), as well as Uterine Contractions (UC), non-invasively.
- Automatic NST Mode
- Automatic detection and recording of fetal movement
- Audible and visual FHR alarms
- Y-shaped cable
- Extremely compact and lightweight
Fetal Heart Rate (FHR) Output Signal
Ultrasound Pulsed Doppler, 1.1 MHz
Ultrasound Wave Intensity ≤ 1.5 mW/cm²
Detection Method
Ultrasound Pulsed Doppler (FHR and Fetal
Movement
Measurement
Method - "Instantaneous" Autocorrelation
Range - 50-212 beats per minute (BPM)
Accuracy - 0.5%
Calibration Point Factory set
Display
FHR - Numeric 50-212 PBM
Heartbeat Rhythm - Heart symbol color changes
with signal quality
Heartbeat Sound Monitoring
Original sound via doppler
Alarms
Selectable FHR upper and lower limits
Selectable alarm delay setting
Tachycardia and Bradycardia audible alarms are
distinctive and simultaneous with visual FHR
display that turns red and blinks.
Fetal Movement (FM)
Detection Source
Ultrasound Pulsed Doppler
Recording
Spike waveform on uterine contraction channel
denotes relative intensity and duration of FM
and/or
Dot marks between FHR and uterine contraction
channels when FM intensity exceeds selected
threshold
Uterine Contraction (UC)
Input Source
Esternal tocodynamometer
Differential amplifier
Frequency response from DC to 0.5 Hz
One-touch zero-level buttonRecorder Recording Method
Auto-balancing thermal pen (2 channels)
8-dot print head for alphanumerics/FM dot
Recording Width
1st channel (FHR)
80 mm (50-210BPM) or
70mm (30-24-BPM)
2nd channel (UC) - 40 mm
Chart Information
Automatic annotation of calibration, date, time,
minute mark and monitoring mode
FHR Tracing
FM Spike Waveform
FM Dot when intensity exceeds present level
UC Curve
Event Mark from remote marker
Time recorded every five minutes
Paper Speed (CM/min) - 1,2, or 3
Paper
Thermosensitive type
Z-folded
External Output Signals
FHR and FHR Alarms
FM
UC
Power Requirements
90-130 VAC, 50/60 Hz, 30VA or
180-240 VAC, 50/60 Hz, 30VAS
Dimensions
8.7W x 9.0H x 9.7D inches
220W x 228H x 246D millimeters
Weight
10 Pounds/4.5 Kilograms
Design and specifications are subject to change without
notice