TOITU DOPPLER MT-325

MT-325 Fetal Monitor

Rugged, lightweight, and portable this small Actocardiograph is an excellent choice for all phases of antepartum fetal monitoring.

Simplicity of use begins with easy chart paper loading and extends to all operational characteristics of the MT-325.
A proprietary feature eases the task of doing fetal nonstress tests (NST).  Fetal Movement (FM) is detected and recorded automatically, concurrent with Fetal Heart Rate (FHR), as well as Uterine Contractions (UC), non-invasively.



  • Automatic NST Mode
  • Automatic detection and recording of fetal movement
  • Audible and visual FHR alarms
  • Y-shaped cable
  • Extremely compact and lightweight



    MT-325 Specifications    
                                                                                      
    Fetal Heart Rate (FHR) Output Signal
         Ultrasound Pulsed Doppler, 1.1 MHz
         Ultrasound Wave Intensity
    1.5 mW/cm²
    Detection Method
         Ultrasound Pulsed Doppler (FHR and Fetal 
              Movement

    Measurement
         Method - "Instantaneous" Autocorrelation
         Range - 50-212 beats per minute (BPM)
         Accuracy - 0.5%
        Calibration Point Factory set

    Display
         FHR - Numeric 50-212 PBM
         Heartbeat Rhythm - Heart symbol color changes
              with signal quality

    Heartbeat Sound Monitoring
         Original sound via doppler

    Alarms
         Selectable FHR upper and lower limits
         Selectable alarm delay setting
         Tachycardia and Bradycardia audible alarms are
              distinctive and simultaneous with visual FHR
              display that turns red and blinks.

    Fetal Movement (FM)
    Detection Source
         Ultrasound Pulsed Doppler

    Recording
         Spike waveform on uterine contraction channel
              denotes relative intensity and duration of FM
                                  and/or
         Dot marks between FHR and uterine contraction
              channels when FM intensity exceeds selected
              threshold

    Uterine Contraction (UC)
    Input Source
        Esternal tocodynamometer
    Differential amplifier
    Frequency response from DC to 0.5 Hz

    One-touch zero-level button
    Recorder Recording Method
         Auto-balancing thermal pen (2 channels)
         8-dot print head for alphanumerics/FM dot

    Recording Width
         1st channel (FHR)
              80 mm (50-210BPM) or
              70mm (30-24-BPM)
         2nd channel (UC) - 40 mm

    Chart Information
         Automatic annotation of calibration, date, time,
              minute mark and monitoring mode
         FHR Tracing
         FM Spike Waveform
         FM Dot when intensity exceeds present level
         UC Curve
         Event Mark from remote marker
         Time recorded every five minutes

    Paper Speed (CM/min) - 1,2, or 3
    Paper
         Thermosensitive type
         Z-folded

    External Output Signals
         FHR and FHR Alarms
         FM
         UC

    Power Requirements
    90-130 VAC, 50/60 Hz, 30VA or
    180-240 VAC, 50/60 Hz, 30VAS

    Dimensions
    8.7W x 9.0H x 9.7D inches
    220W x 228H x 246D millimeters

    Weight
    10 Pounds/4.5 Kilograms

    Design and specifications are subject to change without
    notice

     